Installation
MagnaValve
The MagnaValve must be mounted in a vertical position with an adequate supply of
media above it.
Remote Valve Driver
The Remote Valve Driver should be mounted in an electrical panel that conforms to
the temperature range of 50˚- 120˚ F (10˚- 49˚ C).
Adjustments
MagnaValve
No adjustments are required or recommended. The valve has been tested at the
factory prior to shipment.
Remote Valve Driver
Adjustments to the Remote Valve Driver can be made from the front of the driver;
however, the factory settings should not be changed. The output signal is 10 Vdc. See
page 5 for additional information on the Remote Valve Driver.
Operation
MagnaValve
Signals used to operate the MagnaValve originate at the AC-24 Controller. There are
three conditions necessary for correct operation.
1) Power. 24 Vdc power must be continuously applied to the valve. The valve
requires 2 Amps for operation and a power supply rated at 50 Va. The voltage
should be 24 ±2 Vdc.
2) Enable Signal. The 24 Vdc Enable Signal is used to activate the valve.
3) Input Signal. The analog 0-10 Vdc input signal must be above 0.25 Vdc as a
minimum ow command signal.
AC-24 Controller Operation
Please download the AC-24 Instruction Manual
http://www.electronics-inc.com/data_sheets_and_instruction_manuals_for_wheel_blast_machine_products2.html